The GE Profile II Magnetic Resonance System
is a High Resolution, Whole Body Imaging System Using an
Innovative Open Magnet Design, Operating at 0.2 Tesla.
The System Has Been Designed to Provide
Openness and Patient Comfort for a wide range of
Examinations while Providing Excellent Diagnostic Image
Quality. The Signa Profile System Provides Performance of
Routine and Specialized Clinical Examinations including
Diagnostic Imaging of the Central Nervous System, Body,
Joints, Extremities, and Vascular Anatomy Using a
Comprehensive Range of Proven Pulse Sequences and Image
Enhancement Techniques
The Signa Profile System Consists of:
 |
A Compact Open Magnet With Enclosure |
 |
High Performance Gradient System for
Reduced Scan Times and increased Scanning Flexibility |
 |
Advanced Digital RF System for Single
Channel Receive and Future Expandability to Multiple
Channel Receive Operation |
 |
Application Specific Imaging Coils |
 |
Ergonomic Operator Workstation with 19
inch High Resolution/High Luminescence Black and White
Monitor, and Integrated Physiological Waveform LCD
Display |
 |
Icon Driven, Single Screen, Intuitive
User Interface Enhances System productivity |
 |
Distributed Processing Architecture
allows Multiple Functions - Including Simultaneous Data
Acquisition and Reconstruction to Help Increase System
Productivity |
 |
Patient Table That Includes Lateral
Movement to Facilitate Scanning at magnet Isocenter for
Off-Axis Examinations |
Magnet:
Permanent, NdFeB Material, Vertical Field
Magnet Operating at 0.2 Tesla.
Enclosure Control Panel is Located Above the
Patient Table to Activate:
 |
Table Motion (Lateral And In/Out) |
 |
Alignment Lights and Landmark |
 |
Scan Start, Pause, And Stop |
 |
Status Indicator Display Is Locate On
Magnet Enclosure, Indicating: |
 |
Cradle Position |
 |
Remaining Scan Time |
 |
System Status |
 |
Safety Controls Include An Emergency Of f
Switch Located On both The operator Workstation And
Magnet Enclosure. |
Patient Comfort Features:
 |
Two-Way Intercom |
 |
Mirror Incorporated In Head Coil |
 |
Patient Call Button |
Gradient Subsystem:
Signa Profile System Includes a High
Efficiency Flat Gradient Coils and Software Controlled
Digital Eddy Current Compensation, Designed to minimize
Gradient-Induced Eddy Currents and to provide Controlled and
Uniform Gradient Magnetic Fields in the X, Y, and Z Planes.
 |
Operating Amplitude: l0mT/m |
 |
Rise Time to l0mT/m: 600 microseconds |
 |
Slew Rate: 17 T/m/s |
Radio Frequency Subsystem:
Digital Transceiver
Digital Transceiver Permits Proton Imaging at
8.5 MHz (for 0.2T Operation)
Digital RF Synthesizer Allows precise Phase
Sensitive Techniques With Elimination of Induced Phase Error
Image Artifacts.
The Advanced Digital Filter Eliminates
Frequency Wraparound. In Addition, New Frequency Domain
Digital Filtering techniques:
 |
Further Reduces Phase Errors Compared to
Standard Time-Domain Digital Filtering Methods |
 |
Provide Superior Filtering at High Data
Collection Bandwidths required for fast-Imaging
Techniques. |
RF Coils
Saddle Transmit Body Coil is Contained inside
the Magnet enclosure. Active Decoupling of Body Coil
Enhances Surface Coil Imaging Quality, Particularly With
Large Surface Coils, Allowing High Resolution surface Coil
Imaging of Larger Anatomical Structures.
Quadrature Receive Head coil Has an inside
Diameter of 27 cm (11 Inches) Open Design Incorporates Coil,
Head Holder and Adjustable Mirror System to Promote Patient
Comfort.
Quadrature Receive, Flexible Form Factory
Body Coils Have a 48cm (19 1nches) Length with widths of:
 |
120cm (47 inch) or Medium Size |
 |
150Cm (59 inch) for Large Size |
The 9 Inch General purpose Coil is a Receive
Only Split-Type Design Solenoid Coil Designed for Imaging of
the Shoulder, Knee, Ankle and C-Spine.
RF Power: 2 kW
RF Power Output is Limited Via Hardware and
Software Controls, System is Designed not to Exceed a
Pre-Programmed Rate of Power Deposition per Kilogram of
Patient Body Weight.
Dynamic Bandwidth Capability Allow Operator
to select bandwidth for optimized SNR.
Operator Workstation:
The Signa Profile Operator Workstation is
ergonomically Designed for Ease of Use and Overall operator
Comfort, Including:
 |
CRT Gray Scale Image Monitor, 19 In (48.3
cm Diagonal) |
 |
Monitor is Shielded to Operate in a
Maximum Static Magnetic Field of up 10 Gauss |
 |
An Integrated Physiological Waveform
Liquid Crystal Display (LCD) provide Visualization of
Respiratory and Cardiac Cycle Information. |
 |
Intercom System. Consisting of a Speaker,
bi-directional Microphone and volume Controls Allows
Communication with the Patient at all Times. |
Data Processing System
Dedicated High Speed Computer Processor for
Simultaneous Prescription, Pause Sequence control, Data
Collection and Reconstruction. Specific Subsystems Include:
-
Stand-Alone Host Computer
With 256 Megabyte Main CPU Memory, Expandable to 384
Megabytes.
-
Pulse Sequence Controller
Provides Real Time, High Resolution Waveform Generation
With Ten Nanosecond Resolution.
-
Reconstruction Array
Processor With 92 Megabytes Bulk Acquisition Memory
Standard, Expandable to 512 Megabytes. 94 Milliseconds
FFT Time per 256 x 256 Image. Scan and Reconstruction
Modes Run Simultaneously.
Operational Specifications:
User Interface
New Graphic User Interface on the Signa
Profile System is Designed to Promote Ease-of Use and Fast,
Simple Operation. Icons and One Screen operation Simplify
Scan Set up and Display. Standard Features Provide Automated
Operation of Scan, Patient Management and Data Management
Processes. These Features Include:
 |
Patient Registration: Patient Information
is Entered Prior to Patient Arriving Saving Time and
Improving Efficiency. Multiple Patients can be
Pre-Registered and Stored in System Memory. |
 |
Protocol Link: Pre-defined or Custom
Protocols can be Linked to Register Patient Information.
Selection of the Patient Name Will Automatically
Download Scan Information. The Operator Need only Make
One Selection to be Ready to Scan. |
 |
Prescription Manager: Prescription,
Modification and Control of Acquisition is Organized by
the Prescription manager. Multiple Series can be
Prescribed and Ready to Scan. Scan Location, SAT
Locations and Scan Parameters can Easily be Repeated by
selecting the Copy Feature. This Makes Pre/ Post
Contrast Ob1ique Exams Easier to Prescribe. |
 |
Auto-Scan: When Activated, This Feature
Will Initiate All Prescribed scans with Simplified
Operator Interaction. The operator Prescribes All Series
in one section and Selects Auto-scan |
 |
Auto-View: Images Automatically Display
at the End of Acquisition for Quick review Standard
System Provides 70 Auto-View Images of 256 x 256 Matrix
Expandable to 420 Images With 354 MB. |
 |
“Desktop” Organization: Each process is
Assigned a Dedicated “Desktop” Providing Organization
and Ease-of-Use. Desktop Icons Represent Scan, Display,
Protocol Management, Image Management, GE Tools and
Dedicated Software Packages. |
Application Programmed Protocols:
Pre-programmed , Pre-defined Protocols
provide Anatomic Specific Acquisition Parameters. Customers
Can Use the GE Protocols or Build Their Own Site-Specific
Protocols.
Scan Orientation:
Direct Axial, Sagittal, Coronal, Oblique and
Double-Oblique Plane Imaging
Acquisition Modes:
2D: Multi-slice Images, Including Contiguous
Slices
3D: Volume Imaging Including 12 to 124 slice
Locations in Increments of Two, Depending on Pulse Sequence
Chosen.
Standard Pulse Sequences
 |
2D Inversion Recovery (IR) |
 |
2D Spine Echo (SE) |
 |
2D Sequential and 3D Volume Gradient Echo
Acquisition (GRE) |
 |
2D Multi-planar Gradient Echo (GRE) |
 |
2D/3D Spoiled gradient Echo (SPGR) |
 |
2D Time of Flight (TOF) |
 |
3D Time of Flight |
Imaging Parameters
The Following Enhancements are Compatible
With the Various Pulse Sequences: Flow Compensation,
Respiratory Compensation, Respiratory Triggering, ECG
Triggered Cardiac Gating, Peripheral Pulse Gating, Graphic
Prescription, Spatial Saturation Techniques, Including
Graphic Saturation Prescription, No Phase Wrap, Phase Offset
Multi-Planar (POMP), Variable bandwidth, Image Intensity
Correction, Extended Dynamic Range, Phase Offset, Asymmetric
FOV (Square Pixel and Phase FOV), Odd Nex, and Autoshim.
Slice Thickness/Spacing:
2D: 2.7 to 20 mm Slice Thickness in 0.1 mm
Increments (Depending on Pulse Sequence)
Operator Variable Interslice Spacing
Increments as Small as 0.1 mm. Interlease Option for
Multi-Slice Imaging.
3D: 12-124 Contiguous Slice Imaging,
Depending on Chosen Pulse Sequence, 0.5 to 5.0 mm Slice
Thickness in 0.1 mm increments.
Field of View:
6 to 40 cm in 1 cm Increments, Contiguous in
All Planes.
Ability to Scan Asymmetric FOV and off center
FOV in Frequency and Phase Directions.
Acquisition Matrix Size:
Phase Encoding From 128 to 512 in steps of
32. Frequency Encoding From 128 to 512 in Steps of 32.
Acquisition Times and Pulse Acquisition
Ranges:
By Selecting the Number of Excitations (NEX),
Repetition Times (TR), Number of phase Encoding Steps
(Matrix Size) and number of Slices for 3D, the Operator
Defines the scan Time.
For Imaging Techniques With a Defined
Contrast (TR), Resolution (Matrix) and Signal -to- Noise,
Imaging Time can be optimized by Adjusting Fractional (0.5,
0.75, 1.5) or Multiple NEX (1 to 150)
Adaptive Digital Gating:
The Innovative Adaptive Digital Signal
Processing Technique Reduces the Effects of Gradient
Activity on the ECG Signal. This Technique Provides
Reliable, Consistent –peak Detection and Accurate
Synchronization Heart Activity to Acquire Images which
Minimize Heart, vascular and CSF Motion.
The Cardiac Signals are Displayed on the LCD
Located at the Operator workstation.
The Following Choices are Available for
Cardiac Gated Image Acquisition:
 |
Multi-Slice Single-Phase |
 |
Multi-Slice Multi-phase |
 |
Single-Slice Multi-Phase |
The Gating Package Include the Software, One
set of patient Lead Wires, and One Fiber optic peripheral
Gating Probe
Display and Analysis
Display and Analysis Functions are Accessible
From the Standard Operator Workstation and Include: Auto
View, Next/Prior Image, Next/Prior Exam/Series Sort,
Multiple Image Display, Image Sort, Cine Paging
(Interactive, Auto, Manual Mode), Window/Level Save, Cursor
(Ellipse/Circle/Box/Trace/Crosshair Manual Draw) Report
Cursor, Rulers, Erase Graphics, Measurement Angle/Distance,
Reverse /Rotate, Inverse Video, Multi ROI, Screen Save,
Accelerator Command Bar, Magnification, Pan/Zoom, Scroll,
Image subtraction/Addition, Annotation of Image and
Comments, Reformation (Real-Time/Curved), Cross Reference ,
and Grid.
Image Filtering
The Signa Profile Image Filtering Feature
Provides Post Capabilities to Decrease the Apparent Noise
Level of Images by Applying an Adaptive Filter to the Image
Data. This Feature Utilizes a Hardware Accelerator That
Processes Images in Less Than 2 Seconds Per 256 x 256 Image
While Allowing Full system Simultaneity.
Filming
Page Filming Permits Creation of an Entire
Film with a Single Keystroke.
Film Formats Available are 1:1 to 20:1 and 35
mm Slides.
Multiple Image Formats Allow Filming of Multi
Images in a Single Format Frame
Archiving
Archive of Up to 4000 256 x 256 Matrix Images
on the Re-Writable Magnetic Optical Disk (MOD), (Dual-Sided
5-1/4 inch Removable platter)
Image Networking
Standard DICOM Store Service Class:
 |
Send/Receive DICOM 3.0 Images. |
 |
Standard DICOM Query/Receive Service
Class: |
 |
User Component: Query and Retrieve Image
from DICOM 3.0 Compatible Stations |
 |
Multiple Exams can be Selected and Moved
Between Signa Advantage, CT Advantage and Advantage IC
Systems and the Advantage Windows Workstation. The
System can Pull images from Advantage Windows, Signa
Advantage, CT Advantage and Advantage IC Systems. |
Accessories
 |
Quality Assurance Phantom |
 |
Positioning Pads, Sponges, and
.accessories |
 |
Photoplethysmograph for Peripheral Gating |
 |
Electrodes for ECG Gating |
 |
Bellows for Respiratory Compensation |
 |
Operator Workstation Table |
Fast Spin Echo
The Fast Spin Echo Package Provides the
Capability to Perform 2D Acquisitions on the Signa profile.
RF Pulses are Designed to Reduce SAR and Minimize Image
Blurring. In Addition, Bandwidth may be Varied in the fast
spin Echo Package up to 32 kHz.
2D FSE Allows the Acquisition of T1-Weigted,
Proton-Density and T2-Weighted Spin Echo Studies at
Substantially Reduced Acquisition times by Acquiring
Multiple Phase Encoding Steps per TR. Fast Spin Echo
Includes Single Contrast and Dual Contrast (Proton Density
and T2) Sequences. Features of This Package Include:
 |
Echo Train Length up to 8 |
 |
Shorter Echo Spacing Improves Image
Quality |
 |
Flow Compensation |
 |
Fast Inversion Recovery |
 |
Variable Echo Train Lengths |
 |
2D/3D Fast Gradient Echo |
 |
2D/3D Fast Grass and Past SPGR Pulse
Sequences Allow the Rapid Acquisition of Gradient Echo
Images with Excellent T1 or T2* Weighting |
Interactive Vascular Imaging
The Signa Profile Vascular Display Package (
“Workstation IVI”) Option Permits customization of
Reprojections From Previously Acquired Vascular Images
Either Interactively or Via Explicit prescriptions.
Customization Includes User Defined Volume of Interest
Angles, Tilts, Rotations, Thresholding, and Maximum /Minimum
Intensity Pixel Reprojections
Neuro Imaging Package
Neuro Imaging Package for the Signa Profile
Provides MR Acquisition Software Tailored Specifically for
Brain Imaging Applications. Contents of the Neuro Imaging
Package are as Follows:
 |
Magnetization Transfer Prepared Spin Echo
Pulse Sequence (MTSE) |
 |
Magnetization Transfer Prepared |
 |
Fast Fluid Attenuated Inversion Recovery
Pulse Sequence (FLAIR) |
 |
Flow-Compensated Spin Echo Pulse Sequence
(FCMTSE) |
Advanced Fast Package for Signa
Profile:
Contents of the Advanced Fast Package are as
Follows:
 |
2-16 ETL Capability for FSE |
 |
Split Train FSE Shared Echoes |
 |
Single- Shot Fast Spin Echo (Single-Slice
and Multi-Slice Capability) |