Specifications:
 |
3.5 MHU MRC CT 162 Tube installed 9/2005.
Approximate Tube Count: 41,080 |
 |
Gantry and Table:
 |
Gantry Manufactured:
September 2000. Approximate Count: 626,519 |
 |
Table Manufactured:
October 2000 |
 |
High frequency X-Ray
system with a generator output capacity of 30KW |
 |
ClearView Solid State
Detector. |
 |
Rapid View
Reconstructor. |
 |
Raw Data Disk |
|
 |
Installed Options:
 |
3D |
 |
MPR |
 |
Dental |
 |
Angiography |
 |
DICOM |
|
 |
Operator’s Console and
Workstation:
 |
Console Software: CT
Aura Release 1.5.1 Level 3. February 2004 |
 |
Workstation: Philips
Easyvision 1.3 level 3 |
 |
Scan Control
Environment:
 |
Patient Scheduling
Software |
 |
Scan Acquisition
Mode:
 |
Scanogram |
 |
Serial Scan |
 |
3D (Volumetric
Scan) |
 |
Multi Scan |
|
 |
Image Handling
Environment:
 |
StackView |
 |
DirectMovie |
 |
Image
Processing Software |
 |
Image
Presentation Software |
 |
Image Analysis
Software |
 |
Image Windowing
Software |
 |
Full Volume
Multi Planar Reformatting (MPR) |
 |
EasyPrint Hard
Copy Imaging |
 |
Print Compose
Software |
 |
Protocol Print |
 |
DICOM Archive
to Software |
 |
Network
Interface (Ethernet) |
 |
Operator’s
Console Hardware Composition |
 |
Image Data Dist |
 |
EasyStore
CD-Recordable |
 |
21’’ Flat
Screen Monitor |
 |
21’’ CRT
Monitor |
|
|
|
 |
Features Description:
 |
Gantry and Table:
 |
Scan Rotation
Times: 1, 2, 3, and 4 seconds |
 |
Scan Times: 1, 1.4,
2, 3, and 4 seconds |
 |
Slice Thickness
(All pre-collimated): 1, 2, 3, 5, 7, and 10 mm |
 |
Minimum-Maximum
Field Of View: 4 – 48 cm |
 |
Gantry Aperture: 67
cm |
 |
Gantry Angulations:
+30/-28 degrees |
|
 |
Clear View Solid State
Detector System:
 |
ClearView Detector:
696 channels |
 |
Photon Capture
Efficiency: 99.99% |
 |
Dynamic Range:
1:1,000,000 |
 |
High Contrast
Spatial Resolution: 15 LP/cm at Cut-off |
 |
Low Contrast
Resolution: 3mm at 0.3% at 35mGy (10mm 120 KV) |
|
 |
MRC CT X-Ray Tube:
 |
Anode Heat Storage
Capacity: 3.5 MHU |
 |
Anode Heat
Dissipation, maximum: 735 KHU/min |
|
 |
High Frequency X-Ray
System:
 |
Generator Output
Capacity: 30 KW |
 |
KV Selections: 100,
120, 130, and 140 kV |
 |
mA Selections: 15
to 50 mA in steps of 5 ma; 50 to 100 mA is steps of
10 mA, 120 to 180 mA in 20 mA Steps |
|
 |
RapidView Reconsturtor:
 |
Evaluation in
Parallel with acquisition |
 |
Direct control
during interventional procedures |
 |
Tracking of
contrast flow in real time |
 |
Greater focus on
productivity by eliminating the ‘Dead Time’ due to
image reconstruction |
 |
Prospective and
retrospective reconstruction of overlapping slices |
|
 |
Reconstruction Time:
 |
1.0 sec / image at
512x512 matrix |
|
 |
Raw Data Disk
 |
Storage Capacity:
4.0 Gbytes |
 |
Raw data storage
capacity: 1024 raw data files |
|
 |
PATIENT TABLE
 |
Table Top width:
410mm |
 |
Elevation
travel:470 to 965mm |
 |
Elevation speeds:
30mm/sec and 15/sec |
 |
Longitudinal
travel: 1930mm |
 |
Longitudinal travel
speeds: 100mm/sec, 5mm/sec |
 |
Metal Free scanning
range: 1575mm |
 |
Incremental
accuracy: 0.25mm |
 |
Maximum supportable
weight:225 kg (150 kg at 0.25mm accuracy) |
|
 |
The standard accessory
set includes:
 |
Axial head support
(adult and pediatric) |
 |
Angled wedges for
positioning kyphotic patients |
 |
Coronal head
support with cushion for chin and forehead |
 |
Head support holder |
 |
Forehead and chin
straps (25mm) |
 |
Forehead and chin
straps (40mm) |
 |
Lower back support |
 |
Body straps (50mm) |
 |
Arm support set |
 |
Velcro straps |
 |
Mattress |
|
 |
3D Scan Mode comprises:
 |
Dedicated
volumetric reconstruction algorithm for optimized
image quality |
 |
Maximum scan times
of 100 seconds |
 |
100, 120, 130, and
140 kV selections |
 |
15 mA to 180 mA
selections |
 |
1, 2, 3, 5, 7, and
10 mm slice selections |
 |
Pitch selections
from 0.75 to 3 in steps of 0.25 |
 |
Minimum
Reconstruction index of 0.1 mm |
 |
Direct storage of
Raw Date to Disk |
|
|
|
 |

Contact